SER, SEU, URD AND USE-2: SERVICE AND UNDERGROUND CABLE

Service entrance and underground cable is bought on construction, not color: how many insulated conductors, what the neutral is made of, and whether it is rated for direct burial.

SERSEUURDUSE-2Direct burial

Service cable is the most expensive wire on most small jobs and the most likely to be left over in a long length. A 4/0 SER run that came up 30 feet short leaves 200 feet on the reel, and that reel is worth more than the panel it was going to feed.

We buy SEU, SER, URD, USE-2 and mobile home feeder across Kansas, in copper and aluminum, on full reels, part reels and coils. The quote depends on conductor count, neutral size, insulation and footage, so the tag is where we start. Neutral size is the item most often left out of a description.

Four Names, Four Jobs

SEU and SER are service entrance cable, Article 338. SEU is the older form, most often two insulated conductors with a bare concentric neutral wrapped around them. SER is the round version with three insulated conductors plus a ground. Both are 600 volt assemblies used for service drops, panel feeders and subpanels.

URD and USE-2 are underground. URD is a utility term rather than an NEC cable type: it describes a direct-buried secondary assembly, usually two or three XLPE-insulated aluminum conductors twisted around a bare neutral. USE-2 is a single conductor rated for underground service entrance, 90 degrees wet or dry, sunlight resistant, and permitted in direct contact with the earth.

  • SEU: two insulated conductors with a bare concentric neutral, for single-phase service and heavy appliance feeds.
  • SER: three insulated conductors plus ground, round, for subpanels and interior feeders.
  • URD: triplex or quadruplex direct-burial assembly, almost always aluminum, for yard and pedestal work.
  • USE-2: single conductor, direct burial, also used on service laterals and solar DC circuits.
  • Mobile home feeder: four-wire direct-burial assembly from 2-2-2-4 through 4/0-4/0-4/0-2/0.

How SEU and SER Are Built

SEU carries its neutral outside the insulated cores, wrapped helically as bare strands. That is why SEU is compact and why the neutral is obvious at a glance. SER puts the same conductors in a round jacket with the ground bare or insulated, which is what a subpanel feed requires.

Both are made with XHHW or THHN conductors under a sunlight-resistant jacket, and both are limited by termination temperature. Where SE cable is installed in thermal insulation, the ampacity must come from the 60 degree column, and that is the rule that catches people who read the 90 degree print and size to it.

Service entrance and underground cable
TypeConductorsNeutralVoltageCommon sizesPackaging
SEU2 insulated plus bare concentricBare strands600 V6 AWG-4/0125-1,000 ft coils
SER3 insulated plus groundInsulated or bare600 V6 AWG-4/0125-1,000 ft coils
URD triplex2 insulated plus bare neutralBare strands600 V2 AWG-750 MCM500-5,000 ft reels
URD quadruplex3 insulated plus bare neutralBare strands600 V2 AWG-500 MCM500-5,000 ft reels
USE-2Single conductorNone600 V8 AWG-1000 MCM500-2,500 ft reels
Mobile home feeder4 insulatedInsulated600 V2-2-2-4 to 4/0-4/0-4/0-2/0125-1,000 ft coils

URD, USE-2 and Direct Burial

URD feeds a pedestal, a shop, a well house or a yard light from a transformer. The conductors are XLPE-insulated aluminum twisted around a bare neutral, and the assembly is built to go into the ground without conduit. Neutral sizes run full, two-thirds or one-third of the phase conductor, and that ratio is on the tag.

USE-2 is the single-conductor version of the same idea: 90 degrees wet or dry, sunlight resistant, suitable for direct burial. That is why it appears on service laterals, irrigation pumps and solar arrays. It is not a substitute for building wire inside a wall, and it is not rated for continuous submersion in a wet well.

  • Aluminum is normal for URD and for large USE-2; copper appears in smaller services and retrofit work.
  • Bare aluminum is not installed in contact with earth or masonry, which is why every underground aluminum conductor is insulated.
  • Aluminum terminations need a listed AL/CU connector, an antioxidant where the manufacturer requires one, and the specified torque.
  • A direct-burial assembly still needs the jacket intact; a nick at the reel flange is where moisture starts.

Ampacity and the Neutral

The neutral is where these cables differ from ordinary feeders. A reduced neutral is legitimate for a service carrying mostly line-to-line load, and it is the wrong choice for a panel full of 120 volt branch circuits. Read the neutral size on the tag before valuing the reel.

Ampacity comes from the conductor insulation and the termination, not from the jacket. A 4/0 aluminum URD assembly carries 180 amperes in the 75 degree column; the same conductor reads 205 in the 90 degree column, which a 75 degree lug cannot use. Small sizes are also limited by the service and feeder rules rather than by the insulation alone.

Aluminum ampacity for service and underground cable
Size75°C amperes90°C amperes
2 AWG90100
1/0 AWG120135
2/0 AWG135150
4/0 AWG180205
250 MCM205230
350 MCM250280
500 MCM310350

Photograph and Note

The tag on a URD reel states conductor size, neutral size, voltage class and footage. On SEU and SER the print is on the jacket and the neutral is visible at the cut end. Two photographs cover most of what a quote needs, and a third showing the flange settles whether the reel can be handled on site.

Wire and cable is the whole offer. Transformers, switchgear, breakers, motor control centers, generators, chillers and machinery are not bought, however close they sit to the cable. Aluminum service and underground stock is covered further under aluminum wire, interior branch-circuit stock under building wire, and the quote form takes either.

  • The reel tag, showing phase size, neutral size and footage.
  • A cut end, where the conductor count and the bare neutral are visible.
  • The jacket print, showing the type and temperature rating.
  • The reel flange, since a 5,000-foot URD reel needs equipment to move.
  • Whether the cable has been buried and pulled back out, and for how long.

Send the tag and both cut ends. Service cable is priced from the neutral and the jacket, and one photograph shows both. If the tag is gone, measure the bare neutral and say so.

Large blue-flanged and wooden reels of black cable lined up on bare dirt under a wide sky
Underground cable is heavy per foot, so a part reel of URD is still a substantial lot.

Straight answers

QUESTIONS ABOUT THIS CABLE

What is the difference between SER and SEU?

SEU has two insulated conductors with a bare concentric neutral and is used for single-phase service. SER is round, with three insulated conductors plus a ground, and is used for subpanels and three-wire feeders. The cut end shows the difference at once.

Can URD be used for a service entrance?

URD is a utility distribution product, not an NEC cable type. It is common on the line side and on customer-owned laterals where the authority having jurisdiction accepts it. USE-2 is the recognized single-conductor choice for underground service entrance.

Why is the neutral smaller than the phase conductors?

A reduced neutral is sized for the unbalanced load a service actually carries, which can be small on a line-to-line load such as a shop full of motors. It is not adequate for a panel dominated by 120 volt circuits.

Do you buy cable that has been in the ground?

Yes, if it was pulled clean and the jacket is intact. Photograph the jacket at several points and say how long it was buried. Cable with nicks, a crushed jacket or water inside the strands is valued lower, and we will explain why.

Do you take mobile home feeder?

Yes, in the usual 2-2-2-4 through 4/0-4/0-4/0-2/0 builds, copper or aluminum, on coils and part coils. It is a common leftover on rural work and is priced as a four-wire direct-burial assembly.

Request a quote

TELL US WHAT YOU HAVE

Send the details and photos of the reels. A tag photo and a jacket photo answer most of our questions, so you do not have to measure anything twice.

  • Wire and cable only: no transformers, switchgear, breakers, MCCs, generators or machinery.
  • Full reels, partial reels, spools, coils and boxed stock all welcome.
  • Statewide Kansas pickup arranged after we agree on the load.
  • Prefer to talk it through? Call +1 (614) 715-3047.

Surplus wire quote form

Fields marked * are required. Everything else helps us price it faster.

Who you are
The wire
Description and loading
Photos of the wire
A close, readable shot of the tag is the single most useful photo you can send.
The print on the cable jacket shows the type, size, voltage and standard.
Step back so we can see reel diameter, footage left and how it is stored.

Up to three files, 10 MB combined. On a phone you can take the photo on the spot. More reels than that? Send this form once, then call +1 (614) 715-3047 and we will take the rest by text or email.

Goes straight to saleselectricalbuyers@gmail.com. We reply to the phone number or email you give us. If the form does not send, email the photos directly to saleselectricalbuyers@gmail.com or call +1 (614) 715-3047.

SELL YOUR SURPLUS WIRE IN SER, SEU, URD AND USE-2

Send the tag photos and we will price the lot, partial reels included.

Sell your surplus wire